Meter Configuration Mapping

This topic correlates supported meter run types with their respective configuration data groups and input data groups. While the tables provide a "complete" picture of the applicable data groups for a given run type, you might not need to poll all input data groups; you determine which input data is applicable to your needs. In general, meter configuration data groups must be polled, but supporting input data groups can be polled on an ad-hoc basis.

To supply data to CygNet Measurement, ensure that all required support data groups for a given meter type are instantiated in the remote device editor. Locate the FmsConfig data group in the applicable device template file and survey its supportDg element for the list of possible support data groups you must instantiate. Exactly which support data groups varies by meter type.

For information about which data groups supply input data, see Data Groups.

Gas Meter Run – AGA-8 Detailed Compression

The following table correlates gas calculation types with configuration and input data groups.

Type   Configuration Data Groups Input Data Groups
FlwRunCfg GasQlty Aga3Cfg Aga7Cfg VConeCfg InDpCfg InPulseCfg InSpCfg InTempCfg
AGA-3 1985 Check Check Check Check Check Check
AGA-3 1992 Check Check Check Check Check Check
AGA-7 Check Check Check Check Check Check
AGA-11 Check Check Check Check
V-Cone Check Check Check Check Check Check

Gas Meter Run – NX-19 Compression

The following table correlates gas calculation types with configuration and input data groups.

Type     Configuration Data Groups Input Data Groups
FlwRunCfg NX-19 Aga3Cfg Aga7Cfg VConeCfg InDpCfg InPulseCfg InSpCfg InTempCfg
AGA-3 1985 Check Check Check Check Check Check
AGA-3 1992 Check Check Check Check Check Check
AGA-7 Check Check Check Check Check Check
AGA-11 Check Check Check Check Check
V-Cone Check Check Check Check Check Check

Liquid Meter Run

The following table correlates liquid input types with configuration and input data groups.

Type       Configuration Data Groups   Input Data Groups
FlwRunCfg LiquidCfg InMassCfg InPulseCfg InVolCfg InDensCfg InSpCfg InTempCfg InWCutCfg
Mass (Pulse) Check Check Check Check Check Check Check
Mass Flow (Coriolis) Check Check Check Check Check Check Check
Vol (Pulse) Check Check Check Check Check Check Check
Vol Flow (Coriolis) Check Check Check Check Check Check Check

Water Meter Run

The following table correlates water input types with configuration and input data groups.

Type       Configuration Data Groups   Input Data Groups
FlwRunCfg LiquidCfg InMassCfg InPulseCfg InVolCfg InTempCfg
Mass (Pulse) Check Check Check Check
Mass Flow (Coriolis) Check Check Check Check
Vol (Pulse) Check Check Check Check
Vol Flow (Coriolis) Check Check Check Check

Back to top